Glaucoma
Diagnostic procedures for glaucoma
Organic examination
After taking the patient's medical history, the examination usually begins with the slit lamp. The anterior segments of the eye are assessed, and in some cases the fundus is also examined at this stage if the pupil is narrow.
Gonioscopy
In order to enable individual differentiation and classification of the findings, inspection of the chamber angle is necessary. The chamber angle refers to the structure of the eye between the cornea and the iris (rainbow membrane). The chamber angle is where the aqueous humor is “drained” from the eye and is often pathologically altered in glaucoma.
Direct assessment is not possible due to the curved cornea (because of total reflection). Therefore, a contact lens is placed on the anesthetized eye during gonioscopy.
Eye pressure measurement
The measurement of intraocular pressure can be done by different methods, sitting or lying down. Nowadays, the so-called non-contact tonometers are often in use. They allow the internal pressure to be determined by the measurement of a defined air pulse and of corneal deformation.
Measurement of the dynamic intraocular pressure conditions with the Pascal Contour Tonometer:
The result of the examination provides decisive information on the perfusion of the eye, the most important protective factor against glaucoma. With this measurement, we can tell you even more precisely, if there is a risk of glaucoma and if a treatment is necessary.
Functional tests
Field of vision, perimetry
As a result of damage to the optic nerve, glaucoma causes (increasing) defects in the perception of the visual field outside central vision.
The task of "perimetry" is to use targeted examinations to examine different areas of the visual field and, as early as possible, to detect a decrease in the sensitivity of these areas or to control the course of visual field defects.
Methods
- Goldmann perimetry
- Automatic perimetry
- FDT ("Frequency doubling technology")
This visual field examination allows a particularly sensitive diagnosis for the early detection of glaucoma-related defects. It specifically tests the retinal sites that are affected early in glaucoma.
Laser measurement of the eye
As a precaution, we offer you a special program, which we would like to introduce to you. These benefits are not included in the scope of benefits of the statutory health insurance.
Non-contact measurement of corneal thickness
The measurement of "normal" eye pressure (10-20 mmHg) does not exclude the diagnosis of glaucoma. To note is the corneal thickness when measuring intraocular pressure. A cornea that is thicker than the "norm" gives the fasle information of a higher intraocular pressure. Too thin a cornea covers up an incresased pressure.
Surveying the optic nerve head with the Heidelberg Retina Tomograph (HRT III)
For further improvement in glaucoma diagnosis, we offer the examination of the optic nerve with a three-dimensional measurement of the optic nerve head with a laser scanner, the HRT III.

▲ healthy optic nerve
Thus, a diagnosis in the early stages and a later follow-up for glaucoma are possible. During the process a comparison of the many precisely determined values of the optic nerve surface is possible and thus the detection of even the smallest changes.
The HRT III examination is the only objective assessment of the optic nerve and thus provides an independent follow-up over the years.

▲ Optic nerve changed by glaucoma