Diagnostic procedures for glaucoma

Organic examination

After taking the patient's medical his­tory, the exa­mi­na­tion usually begins with the slit lamp. The anterior seg­ments of the eye are asses­sed, and in some cases the fundus is also exa­mined at this stage if the pupil is narrow.

Gonioscopy

In order to enable individual diffe­ren­tiation and classi­fi­cation of the findings, inspection of the chamber angle is necessary. The chamber angle refers to the structure of the eye bet­ween the cornea and the iris (rainbow mem­brane). The chamber angle is where the aqueous humor is “drained” from the eye and is often pathologically altered in glaucoma.

Direct assessment is not possible due to the curved cornea (because of total reflection). Therefore, a contact lens is placed on the anesthetized eye during gonioscopy.

Eye pressure measurement

The measurement of intraocular pres­sure can be done by different methods, sitting or lying down. Nowadays, the so-called non-contact tonometers are often in use. They allow the internal pressure to be determined by the measurement of a defined air pulse and of corneal deformation. 

Read more

Measurement of the dynamic intraocular pressure conditions with the Pascal Contour Tonometer:

The result of the examination provides de­ci­sive information on the perfusion of the eye, the most important pro­tec­tive factor against glaucoma. With this measurement, we can tell you even more precisely, if there is a risk of glaucoma and if a treatment is necessary.

Functional tests

Field of vision, perimetry

As a result of damage to the optic nerve, glaucoma causes (increasing) defects in the perception of the visual field outside central vision.
The task of "perimetry" is to use tar­ge­ted examinations to examine different areas of the visual field and, as early as possible, to detect a decrease in the sensitivity of these areas or to control the course of visual field defects.

Methods

  • Goldmann perimetry
  • Automatic perimetry
  • FDT ("Frequency doubling technology")

This visual field examination allows a particularly sensitive diagnosis for the early detection of glaucoma-related defects. It specifically tests the retinal sites that are affected early in glau­coma.

Laser measurement of the eye

As a precaution, we offer you a special pro­gram, which we would like to intro­duce to you. These benefits are not included in the scope of benefits of the statutory health insurance.

Non-contact measurement of corneal thickness

The measurement of "normal" eye pressure (10-20 mmHg) does not exclude the dia­gno­sis of glaucoma. To note is the corneal thickness when measuring intraocular pressure. A cornea that is thicker than the "norm" gives the fasle information of a higher intraocular pressure. Too thin a cornea covers up an incresased pressure.

Surveying the optic nerve head with the Heidelberg Retina Tomograph (HRT III)

For further improvement in glaucoma diagnosis, we offer the exam­in­ation of the optic nerve with a three-dimen­sio­nal measure­ment of the optic nerve head with a laser scanner, the HRT III.

healthy optic nerve

▲ healthy optic nerve

Thus, a diagnosis in the early stages and a later follow-up for glaucoma are possible. During the process a com­pa­ri­son of the many precisely determined values of the optic nerve surface is possible and thus the detec­tion of even the smallest changes.

The HRT III examination is the only objective assessment of the optic nerve and thus provides an independent follow-up over the years.

Optic nerve changed by glaucoma

▲ Optic nerve changed by glaucoma

Do you need more information or
would you like advice?

The team at the Potsdam Eye Clinic will be happy to advise you.

© Potsdamer Augenklinik. All rights reserved.